Autorzy
Tomasz Poboży, Konarski Wojciech, Martyna Hordowicz
Streszczenie
BACKGROUND: When a conservative management of gonarthrosis yields unsatisfactory results, a total knee arthroplasty (TKA) is recommended as an alternative approach. The implant survival is crucial for the long-term success of the procedure. However, in case of patients with retained hardware after past orthopedic procedures, providing correct alignment of the implant, which contributes to its longevity, is especially challenging. Here we present the use of an intra-operative ultrasonography for implant positioning in a 83-year-old male, undergoing TKA, without hardware removal, which was contraindicated due to his advanced age and comorbidities. Other imaging modalities taken into consideration are also described. CASE PRESENTATION: The right knee joint was approached with anterior incision. A femoral guide was introduced extramedullary. Ultrasonography was used to pinpoint the center of the femur's head. Tibial's guide was introduced intramedullary followed by a standard cut of the proximal part. Cemented ZIMMER NEXGEN prosthesis was used. Layered closure was applied. The placement of implant in neutral axis was confirmed on radiographs. CONCLUSIONS: Our case demonstrates that ultrasonography might be helpful during TKA-procedure for implant positioning. However, more studies are needed to evaluate accuracy and application of ultrasound in the intraoperative settings.
Streszczenie pochodzi z bazy OpenAlex (CC0) i może być w języku publikacji.
Informacje bibliograficzne
- Autorzy
- Tomasz Poboży, Konarski Wojciech, Martyna Hordowicz
- Tytuł
- TKA with retained hardware guided by intraoperative ultrasonography - a case report.
- Źródło
- BMC surgery
- Rok
- 2019
- ISSN
- 1471-2482
- DOI
- 10.1186/s12893-019-0585-6
- Cytowań
- 4
- Bibliografia
- 15 pozycji
Inne publikacje z tej dziedziny
Ultrasonographic Assessment of Meniscus Damage in the Context of Clinical Manifestations
Medicina
Evaluation of Remodeling and Extrusion of Polyurethane Meniscal Implants after Meniscus Reconstruction using Ultrasonography
Current Medical Imaging Reviews
Hip fusion takedown with total knee and hip arthroplasty in a patient with end-stage chronic kidney disease – a case report and narrative literature review
Orthopedic Reviews
Zobacz też (publikacje powiązane)
- Surgical outcomes of intramedullary nailing for diaphyseal atypical femur fractures: is it safe to modify a nail entry in bowed femur?2017
- A STUDY ON FRACTURE OF FEMUR SHAFT TREATMENT WITH INTRAMEDULLARY INTERLOCKING NAILING2021
- Outcome of Elastic Stable Intramedullary Nail in Length Unstable Diaphyseal Femur Fractures in Children: A Case Series2020
Sugestie z bazy OpenAlex (CC0) na podstawie cytowań i współautorów.